The values to be measured are:
As the tests are carried out in flight, this load cell should be able to operate and be compensated at low temperatures (-60°C). It should also have to operate under low pressure (5,000 Absolute Pa).
In collaboration with the customer, SENSY has developed and manufactured a specific force transducer combining torque and force measurement.
- Output signals
- Torque : 0,6 mV/V (Wheatstone Bridge)
- Force : 1,0 mV/V (idem)
- Dimensions
- Diameter : 70 mm
- Thickness : 24 mm
- Mounting with M4 screws
- Weight : 208 g
- Material : Aircraft grade aluminium
- Tests
- Non-linearity measurement
- Force : 0,1 %
- Torque : 1 %
- Diaphony measurement (crosstalk) between the two channels : 0,6 %
- Sensitivity and zero compensation in the temperature range of -50 to +40°C.
- Non-linearity measurement
- Special condition : Insensitivity to low pressure
Applications :