Comment configurer les produits de la famille PAX pour récupérer la valeur affichée sur mon PC ou mon automate?

Réponse:

Configuration du Pax

  1. Configuration RS232
    1. PAr pour entrer dans le menu
    2. aller dans le menu 7 Srl avec F1
    3. bAUd = 9600
    4. dAtA = 8
    5. Addr = 0
    6. Abru = yes
    7. OPT = yes
    8. 6roSS = No
    9. tArE = no
    10. IMP = yes
    11. tot = no
    12. HILO = no
    13. Press PAR (sortir)
  2. Configuration fonction:
    1. Press PAR
    2. aller dans le menu 2 FNC
    3. Usr-1 = Print
    4. sortir
  3. Configuration Hardware:
    Connecter le terminal 7 (COM) au terminal 8 (USR1).
    Le Pax envoi sur la liaison RS232, la valeur lue.
Array ( [0] => Array ( [id_gomakoil_faq_category] => 1 [link_rewrite_no] => [active] => 1 [position] => 1 [date_add] => 2017-04-12 11:41:35 [color] => #000000 [id_lang] => 2 [id_shop] => 1 [name] => Electronics [description] => [meta_title] => Electronics FAQ SENSY [meta_description] => [meta_keywords] => [link_rewrite] => electronics )) 1 Array ( [0] => Array ( [id_gomakoil_faq] => 32 [id_gomakoil_faq_category] => 1 [link_rewrite_no] => [most] => 0 [association] => 0 [hide_faq] => 0 [name] => Admin [email] => no [by_customer] => 0 [position] => 16 [active] => 1 [date_add] => 2019-07-01 10:28:49 [as_url] => 0 [id_lang] => 2 [id_shop] => 1 [question] =>

Configuration of the pax family products in order to recover the value displayed on my PC or my PLC.

[answer] =>

PAX configuration 

I) RS232 configuration
 1) Press PAR to enter in the menu
 2) Go up to menu 7 Srl  with F1
 3) bAUd = 9600
 4) dATA = 8
 5) Addr = 0
 6) Abru = yes
 7) Opt = yes
 8) 6roSS = No
 9) tAre = no
 10) IMP = yes
 11) Tot = no
 12) HI LO = no
 13) Press PAR (exit)

II) Function configuration
 1) Press Par
 2) Go to menu 2 FNC
 3) Usr-1 = Print  
 4) exit

III) Hardware configuration
 Connect the terminal 7 (COM) to terminal 8 (USR1)
 In this configuration, PAX send continuously the value displayed on the RS232 link.